The Intraveneous
Module (IVM) can check admixture compatibility as a clinical review
when the order is placed. THIS SECTION IS HIDDEN: In addition, multiple orders can be
checked for compatibility from the Patient Profile.
For more information, see the First
Databank website.
To Enable Checking, go to
Utilities / Options / Clinical Reviews
Check the box for intra-order IV compatability warnings:

During Clinical Checks on an order for an IV, the system will check
for IV Compatibility. Any incompatibilities will appear as a
clinical review.
THIS SECTION IS HIDDEN: By selecting orders on a patient profile, and right clicking on the
last order, choose "IV Compatibility Check" from the menu. The system will do IV
Compatibility checking. Results are found if clinical studies have been
done. Option to save the compatibility results as a Clinical
Review.
Example Clinical Review:
Order includes Amphotericin INJ and
Normal Saline. Clinical Review for Type: IV Incompatibility,
Problem: Drug in Solution, Details:
2 Incompatible Studies
INCOMPATIBLE Drug in Solution study. Grp#[000785]
PHYSICALLY INCOMPATIBLE
INCOMPATIBLE Drug in Solution study. Grp#[000785]
PRECIPITATE FORMS WITHIN 2 HR. DRUG CONCENTRATION OF 43% OF INITIAL
AMOUNT IN 2 HR
|